Wrong-site surgery (WSS) is a well-known type of medical error that continues to occur in healthcare facilities. Wrong-site surgery involves all surgical procedures performed on the wrong patient, wrong body part, wrong side of the body, or wrong level of a correctly identified anatomic site.1,2 Wrong-patient surgery may include patients who were never scheduled for a procedure, procedures performed that were not scheduled, and procedures scheduled correctly in which a different one was performed.2

The National Quality Forum (NQF) defines surgery as “an invasive operative procedure in which skin or mucous membranes and connective tissue is incised or an instrument is introduced through a natural body orifice. Surgery begins, regardless of setting, at the point of surgical incision, tissue puncture, or the insertion of an instrument into tissues, cavities, or organs.”3

Research published by the Patient Safety Authority revealed that these events occur on average of 1.42 WSS events per week in Pennsylvania.4 While it is true that a majority of the WSS events occur in the perioperative areas, a steady number of these events arise outside of the operating theatre in areas such as interventional radiology (IR).

In our December 2020 study published in Patient Safety, research found that “The frequency of WSS was consistently greater in the hospital OR (operating room) than IR; nevertheless, IR experienced a range of 6 to 13 WSS events per year, over the 5-year period.”4

Ongoing research into reported WSS events has revealed an alarming finding. For the period January 1, 2023, through March 31, 2023, there were eight WSS events originating from interventional radiology. These reported WSS events (examples below) included wrong site, wrong side, and wrong procedure cases. The number of IR WSS cases in the first quarter of 2023 was the highest quarterly total since the PSA initiated including procedural WSS events occurring outside of the perioperative setting in 2015.

“A patient goes to interventional radiology (IR) for nephrostomy tube placement. Upon return to the inpatient unit, it is realized that the tube was placed on the wrong side. The patient returns for the correct tube placement the following day.”

“… patient with a compression fracture of T-12 vertebra … underwent a kyphoplasty in IR … after reviewing CT results, MD discovered the T-12 fracture remained with kyphoplasty being performed on T-11 …”

In 2008, the Standards of Practice Committee of the Society of Interventional Radiology released the current “Quality Improvement Guidelines for Preventing Wrong Site, Wrong Procedure, and Wrong Person Errors: Application of the Joint Commission ‘Universal Protocol for Preventing Wrong Site, Wrong Procedure, Wrong Person Surgery’ to the Practice of Interventional Radiology.”5 These guidelines supplement The Joint Commission Universal Protocol6 as well as the PSA’s Principles for Reliable Performance of Correct-Site Surgery7 and the PSA/Department of Health Final Recommendations to Ensure Correct Surgical Procedures and Correct Nerve Blocks.8

We encourage facilities to review/revise their universal protocol policies and procedures and monitor for compliance to decrease the likelihood of a future WSS event both in the perioperative areas as well as the interventional medicine departments.